Power Distribution Panels

Power Distribution Panels Built in Houston, Texas

WETS AI builds industrial power distribution panels in Houston that feed motors, control panels and instruments across a process. Each panel is built to UL 508A with the disconnects, breakers, transformers and DC supplies your system needs, and every output is checked at power-up before it ships.

Inside the Panel

What Goes Into a Power Distribution Panel

A power distribution panel takes one incoming supply and splits it safely into the circuits the rest of your system needs, from three-phase motor feeds to 24 VDC for instruments.

  • Main disconnect
  • Branch breakers or fused disconnects
  • Control power transformers
  • 120 VAC distribution
  • 24 VDC power supplies
  • Surge protection
  • Power meters
  • Spare circuits
Power distribution panel with contactors and power wiring
Power distribution panel with contactors and power wiring
One-Line

How Power Flows Through the Panel

A one-line drawing shows how power enters the panel and divides into protected branch circuits.

  • One main disconnect isolates the whole panel
  • Each branch has its own breaker or fuses, sized to its load
  • A control transformer supplies 120 VAC control power
  • 24 VDC supplies feed instruments and PLC I/O
Simplified one-line diagram: 480 V three-phase supply through a main disconnect to a bus, which feeds motor branch breakers, a 480/120 VAC control power transformer and 24 VDC power supplies for instruments and PLC I/O.
Planning

Planning the Distribution

We start from your load list: every motor, panel and instrument the panel will feed. That sets the incoming rating, the branch protection and the size of the control transformer and DC supplies, with spare capacity agreed up front.

The available fault current at your site sets the short-circuit current rating the panel needs. We select the main and branch devices to meet it and mark the rating on the nameplate.

Illustration of a power distribution panel backplate: a main disconnect and power meter, a row of branch circuit breakers, a control power transformer with 120 VAC breakers and surge protection, and 24 VDC power supplies with outgoing terminals.
Power-Up Checks

What We Check When the Panel Is First Energized

Before a power distribution panel leaves our shop, we power it up and confirm every circuit behaves as drawn.

Problems found here cost minutes. Found on site, they cost days.

CheckWhat we confirm
Incoming voltageMatches the nameplate rating of the panel
Phase rotationCorrect, so motors fed from the panel turn the right way
Control transformerSecondary voltage is correct under load
24 VDC power suppliesOutput voltage is correct on every supply
Branch circuitsEach circuit is energized as drawn and protected as specified

These checks are part of the 13-point test every panel passes. See testing, FAT and SAT.

How We Build It

From Load List to Tested Panel

01

Review the loads

Load list, supply and fault current are reviewed with you.

02

Size and select

Disconnect, branch protection, transformer and DC supplies are sized.

03

Build to UL 508A

The panel is assembled, wired, marked and inspected.

04

Test and record

Every power-up check is completed and recorded before shipping.

FAQ

Power Distribution Questions

Do you build panels with control power transformers?

Yes. We size the control transformer for the control load with margin, and check its output at power-up.

Can the panel feed both motors and instruments?

Yes. A single panel can provide three-phase motor feeds, 120 VAC control power and protected 24 VDC circuits for instruments.

Do you mark the SCCR on power distribution panels?

Yes. We select components to meet the available fault current at your site and mark the short-circuit current rating on the nameplate.

Can you add power metering?

Yes. We can include power meters on the incoming supply or on individual feeders.

Which enclosure types do you build?

Mostly NEMA 1 for clean indoor rooms, NEMA 3R for outdoor sites, NEMA 4 for hose-down areas and NEMA 4X where corrosion is a concern. Tell us where the panel will be installed and we will recommend a rating.

Related

Related Panels & Services

UL 508A Control Panels

What the UL 508A label covers, how SCCR is set, and what we check before a panel is labeled.

Request a Quote

Need a Power Distribution Panel?

Send your load list or one-line diagram. We will size the panel and quote it, with a schedule.