Review hazards
HAZOP findings and SIL identification set the safety functions.
WETS AI engineers and builds control panels for thermal processes in Houston, Texas: thermal oxidizers, boilers, process heaters and furnaces, including the burner management systems that keep combustion safe. Each panel is built to UL 508A, programmed in-house and tested before it ships.
Thermal equipment combines high temperatures, fuel and air, so the controls have two jobs: run the process efficiently and shut it down safely when something goes wrong.

A burner management system (BMS) makes sure a burner can only light, and keep running, when it is safe. It purges the combustion chamber before ignition, proves the pilot and main flame, watches the flame continuously, and closes the fuel safety shutoff valves the moment a safety condition is lost.
We design and build BMS panels to the combustion safety codes that apply to your equipment, and keep the safety logic separate from the normal process control. Every interlock is tested before the panel ships.
A burner only lights once every safety condition is proven, and the fuel is shut off the moment one is lost.
A thermal oxidizer has to hold its chamber temperature high enough to destroy the pollutants in the process air, while the process upstream keeps running. The control system manages burner firing, the fan, dampers or valves that bring in process air, and the temperature records operators and permit reviewers ask for.
We agree how the oxidizer should respond to every upset, such as a temperature drop or a fan failure, in the control narrative before building.
The oxidizer panel holds the chamber hot enough to destroy the pollutants, while the burner management system keeps the burner safe.
HAZOP findings and SIL identification set the safety functions.
Start-up, normal running, shutdown and trips are agreed.
The panel is built to UL 508A and programmed in-house.
Each interlock and shutdown is proven at FAT, then again at SAT.
Yes. We design and build BMS panels for boilers, heaters, furnaces and thermal oxidizers, with the safety logic kept separate from the process control.
Thermal oxidizers, boilers, process heaters and furnaces, including their burner management, temperature control and fan drives.
Yes. Every interlock, trip and shutdown is simulated and tested at FAT, and verified again on site at SAT.
Yes. We work from the supplier's requirements and agree the control narrative with both of you before building.
Mostly NEMA 1 for clean indoor rooms, NEMA 3R for outdoor sites, NEMA 4 for hose-down areas and NEMA 4X where corrosion is a concern. Tell us where the panel will be installed and we will recommend a rating.
Control narratives, HAZOP and SIL identification, process flow diagrams and panel drawings.
Drives, bypass, reactors and cooling for pumps, blowers and fans.
The 13 checks every panel passes, plus witnessed FAT and SAT on site.
Tell us about the equipment and burner. We will review the safety requirements with you and quote the panel.