Control Panel Glossary

A plain-English glossary of the terms used in industrial control panel specifications, quotes and drawings, from SCCR and UL 508A to PLC, HMI, VFD, FAT and SAT. Each definition is short, and links to a full guide or page where there is one.

A to Z

Terms and Definitions

A

Alternation
Swapping which pump or motor runs first each cycle, so run hours are shared. See pump control panels.
As-built drawings
Drawings updated to show the panel exactly as it was built and tested, including any changes.

B

BMS (burner management system)
The safety controls that purge, light, prove flame and shut off fuel on a burner. See thermal process panels.
BOM (bill of materials)
The list of every part in the panel, with manufacturer, part number and quantity.
Build-to-print
Building a panel exactly to the customer's drawings and BOM. See build-to-print assembly.
Bypass
A contactor arrangement that lets a motor run across the line if its drive is out of service.

C

Contactor
An electrically operated switch for motors and other power loads.
Control narrative
A plain-language description of how the system should operate. See how to write a control narrative.
Control transformer
A transformer that steps supply voltage down to control voltage, often 120 VAC.

D

DIN rail
The standard metal rail that breakers, terminals, relays and many PLCs clip onto.
Disconnect
The switch or breaker that isolates power to the whole panel.

E

E-stop (emergency stop)
A red mushroom-head button that stops hazardous motion, usually through a hard-wired safety circuit.
EtherNet/IP, PROFINET, Modbus TCP
Industrial Ethernet networks that connect PLCs, HMIs, drives and remote I/O.

F

FAT (factory acceptance test)
Testing the panel and program in the shop before shipping. See FAT checklist.
Fault current
The current that flows during a short circuit, limited only by the supply. Also called available fault current.
Ferrule
A metal sleeve crimped onto a stranded wire end so it lands cleanly in a terminal.

G

Grounding and bonding
Connecting every metal part that could become live to ground, so a fault trips protection instead of leaving parts energized.

H

HMI (human-machine interface)
The touchscreen operators use to run and monitor the process. See HMI and operator panels.

I

I/O (inputs and outputs)
The signals a PLC reads from and sends to field devices: digital (on/off) and analog (4 to 20 mA, 0 to 10 V).
I/O list
A table of every input and output, with tag, description, signal type and terminal.
Interlock
A condition that stops or blocks equipment to protect people, equipment or the process.
Interposing relay
A relay between a PLC output and a field load, to switch higher current or isolate circuits.

J

Junction box
A field enclosure where cables from devices are terminated and combined. See junction boxes.

K

kA (kiloamperes)
Thousands of amperes. Short-circuit ratings and fault currents are usually stated in kA.

L

Lead-lag
Running one pump or motor as lead and starting a second (lag) when demand rises.

M

Marshalling
Organizing field wiring on terminals so signals reach the right I/O points in a tidy order.
MCC (motor control center)
A large assembly of motor starters and drives in sections. Smaller groups are built as motor control panels.

N

NEMA type
The rating that says what environment an enclosure suits, such as NEMA 1, 3R, 4 or 4X. See NEMA enclosure ratings.

O

Overload relay
A device that protects a motor from overheating by tripping on sustained overcurrent.

P

P&ID
Piping and instrumentation diagram: the drawing of process equipment, piping and instruments.
Permissive
A condition that must be true before equipment is allowed to start.
PLC (programmable logic controller)
The industrial computer that runs the control program. See PLC control panels.
Point-to-point check
Testing every wire from end to end against the drawings.

R

Redline
A drawing marked up by hand to show changes.

S

SAT (site acceptance test)
Testing the installed system on site with real devices. See FAT vs SAT.
SCADA
Supervisory control and data acquisition: software that monitors and controls plants from a central location.
SCCR (short-circuit current rating)
The highest fault current a panel can safely withstand. See SCCR explained.
Soft starter
A device that ramps motor voltage up at start to reduce inrush current.
Spare I/O
Unused PLC inputs and outputs left for future instruments or changes.
Surge protective device (SPD)
A device that limits voltage spikes reaching sensitive equipment.

T

Terminal block
The rail-mounted connector where field and internal wires are landed.

U

UL 508A
The UL standard for industrial control panels. See what is UL 508A.

V

VFD (variable frequency drive)
A drive that controls motor speed by changing frequency and voltage. See VFD control panels.

W

Wire marking
Printed sleeves or labels on each wire end that match the wire number on the drawings.
FAQ

Glossary Questions

Is there a term you would like added?

Call 713-660-9387 or use the quote form to ask. We add common questions to this glossary.

Where can I learn more about UL 508A?

Start with our guide What Is UL 508A?, then the UL 508A control panels page.

Related

Related Guides & Services

What Is UL 508A?

What the standard covers, what the label means and what it does not.

SCCR Explained

How a panel's short-circuit current rating is set, and how to raise it.

Request a Quote

Ready for a Quote?

Send what you have: drawings, an I/O list or a short description of the process. We will reply with questions, a quotation and a schedule.

Call Request a Quote