Water Treatment

Water Treatment Control Panels

WETS AI builds control panels for water treatment systems in our Houston, Texas shop. We engineer, program and test panels for aeration and VOC stripping, filter backwash, ion exchange, PFAS treatment, reverse osmosis and chemical dosing, for municipal water systems, utilities and the companies that supply their equipment.

Our Strongest Field

Water Is Where We Do Most of Our Work

WETS stands for Water Equipment & Treatment Services, and water treatment is the industry we build for most. Our panels run treatment systems that remove contaminants such as arsenic, iron and manganese, radium, radon, hydrogen sulfide, volatile organic compounds and PFAS.

Water systems run around the clock, often unattended, and operators need to trust what the panel tells them. We design for that: clear alarms, safe fallback modes, and remote monitoring when the site needs it.

Water treatment facility with filter vessels controlled by WETS AI panels
Filter vessels controlled by WETS AI panels
Processes

Treatment Processes We Build Panels For

Each treatment step needs its own control logic, alarms and interlocks.

These are the processes we build panels for most often. Many plants combine several of them in one panel.

ProcessWhat the panel controls
Aeration and VOC strippingBlowers, often on VFDs, airflow and level, and the interlocks that protect the blower and tower
Pressure and gravity filtrationFilter run time and differential pressure, automatic backwash sequences, valves and backwash pumps
Ion exchangeService and regeneration cycles, brine or regenerant dosing, rinse steps and flow totalizing
PFAS treatmentLead and lag vessel operation, flow, pressure and the sampling points operators rely on
Reverse osmosisHigh-pressure pump start sequence, permeate and concentrate flow, pressure protection and flush cycles
Chemical dosingMetering pumps paced to flow, tank levels, and alarms for low chemical or pump failure
System View

How One Panel Runs the Whole Train

A typical groundwater treatment train, with the control panel watching and running every stage.

  • Well pump and blower run on the level and flow the plant needs
  • Filters backwash automatically on time or differential pressure
  • Lead and lag vessels switch over without operator action
  • Chlorine dosing is paced to flow, with alarms sent to SCADA
Illustration of a groundwater treatment train: a well pump feeds an aerator with a blower, then pressure filters, then ion exchange or PFAS vessels, then a storage tank with a chlorine dosing pump. A WETS AI control panel monitors every stage and reports to a SCADA workstation.
Swipe sideways to see the whole diagram
Design Details

What Water Panels Need to Get Right

Many treatment sites are outdoors or in humid, chemical-laden rooms, so we build in NEMA 3R, 4 or 4X enclosures and plan cooling for the Texas sun.

Backwash and regeneration sequences have to finish safely even if power drops halfway through, and operators need to be able to run equipment by hand when the PLC is out of service. We agree these behaviors in the control narrative before we build.

  • Hand-off-auto control for key equipment
  • Alarm list agreed with operators
  • Safe restart after power loss
  • Remote monitoring or SCADA connection
  • NEMA 3R, 4 or 4X enclosures
  • Flow, level and pressure trending
Newly installed treatment tank at a customer site
Newly installed treatment tank at a customer site
How We Work

From Process to Running Plant

01

Define

We agree the control narrative with you and the equipment supplier.

02

Design

Drawings and the I/O list follow the narrative.

03

Build and test

The panel is built to UL 508A and proven at FAT.

04

Commission

The system is verified on site at SAT with the real process.

FAQ

Water Treatment Panel Questions

Which water treatment processes do you build panels for?

Aeration and VOC stripping, pressure and gravity filtration with backwash, ion exchange, PFAS treatment, reverse osmosis and chemical dosing, plus the pump stations that feed them.

Can the panel connect to our SCADA system?

Yes. We set up the PLC communications your SCADA system needs and test them at FAT.

Can operators run equipment by hand if the PLC fails?

Yes, where the process allows it. We agree which equipment needs hand control in the control narrative and wire it accordingly.

Do you build panels for equipment suppliers?

Yes. We build panels for companies that supply treatment equipment, so every system they ship has the same tested panel.

Which enclosure types do you build?

Mostly NEMA 1 for clean indoor rooms, NEMA 3R for outdoor sites, NEMA 4 for hose-down areas and NEMA 4X where corrosion is a concern. Tell us where the panel will be installed and we will recommend a rating.

Related

Related Panels & Services

Design & Engineering

Control narratives, HAZOP and SIL identification, process flow diagrams and panel drawings.

Request a Quote

Need a Water Treatment Panel?

Tell us the treatment process and the equipment list. We will come back with questions, a quotation and a schedule.

Call Request a Quote