Review
Motor list, duty and fault current are reviewed with you.
WETS AI builds motor control panels in Houston for pumps, fans, blowers, conveyors and compressors. We select the starter and protection for each motor, calculate and mark the panel SCCR to UL 508A, and record every overload setting during testing.
Every motor needs a way to start and stop it, protection against short circuits, and protection against overload. A motor control panel brings those together for one motor or many, with the control wiring that ties them to your PLC or local switches.

The starting method affects your supply, your cabling and the driven load.
We choose it motor by motor, not one size for the whole panel.
| Method | Best for | Trade-off |
|---|---|---|
| Full-voltage starter | Smaller motors and simple on/off duty | High starting current and a mechanical jolt at start |
| Soft starter | Pumps and fans where a smooth start matters | No speed control once the motor is running |
| Variable frequency drive | Changing flow or speed, energy savings | Higher cost, more heat, and harmonics to manage |
Not sure which fits? Send us the motor list and duty, and we will recommend a method for each motor. For drive panels, see VFD control panels.
Inrush current affects cable sizing, voltage dip on your supply and mechanical stress on the load.
Each motor branch has short-circuit protection sized for the motor and its starter, and an overload set from the motor nameplate full-load current. We record every overload setting during testing, so maintenance has a reference when a motor is replaced.
The panel short-circuit current rating is set by the weakest part of the power circuit. When you tell us the available fault current at your site, we choose starters and protective devices that reach it and mark the rating on the nameplate.

A motor list is the starting point. With these details we can choose a starting method and protection for each motor and price the panel.
Motor list, duty and fault current are reviewed with you.
Starters, protection and overloads are chosen for each motor.
The panel is built to UL 508A, wired and marked.
Electrical checks, functional tests and recorded overload settings.
Typical equipment our motor control panels run.
It depends on the components chosen. Tell us the available fault current at the panel location and we will select starters and protection to meet it.
Yes. Overloads are set from the motor nameplate full-load current you provide, and every setting is recorded during testing.
Yes. We build multi-pump panels with lead and lag alternation and the level controls your system uses.
Yes. We build with Allen-Bradley, Siemens and Schneider Electric components, matching your plant standard.
Mostly NEMA 1 for clean indoor rooms, NEMA 3R for outdoor sites, NEMA 4 for hose-down areas and NEMA 4X where corrosion is a concern. Tell us where the panel will be installed and we will recommend a rating.
Drives, bypass, reactors and cooling for pumps, blowers and fans.
Disconnects, breakers, control transformers and 24 VDC supplies.
What the UL 508A label covers, how SCCR is set, and what we check before a panel is labeled.
Send the motor list or your drawings. We will recommend starting methods and protection, and quote the complete panel.