Motor Control Panels

Motor Control Panels Built in Houston, Texas

WETS AI builds motor control panels in Houston for pumps, fans, blowers, conveyors and compressors. We select the starter and protection for each motor, calculate and mark the panel SCCR to UL 508A, and record every overload setting during testing.

Inside the Panel

What Goes Into a Motor Control Panel

Every motor needs a way to start and stop it, protection against short circuits, and protection against overload. A motor control panel brings those together for one motor or many, with the control wiring that ties them to your PLC or local switches.

  • Full-voltage starters
  • Reversing starters
  • Soft starters
  • Variable frequency drives
  • Motor circuit protection
  • Overload relays
  • Control power transformer
  • Hand-off-auto switches
Motor control panel with starters and overload relays
Motor control panel with starters and overload relays
Starting Methods

Choosing How Each Motor Starts

The starting method affects your supply, your cabling and the driven load.

We choose it motor by motor, not one size for the whole panel.

MethodBest forTrade-off
Full-voltage starterSmaller motors and simple on/off dutyHigh starting current and a mechanical jolt at start
Soft starterPumps and fans where a smooth start mattersNo speed control once the motor is running
Variable frequency driveChanging flow or speed, energy savingsHigher cost, more heat, and harmonics to manage

Not sure which fits? Send us the motor list and duty, and we will recommend a method for each motor. For drive panels, see VFD control panels.

Starting Current

Why the Starting Method Matters

Inrush current affects cable sizing, voltage dip on your supply and mechanical stress on the load.

  • A full-voltage start draws several times full-load current
  • A soft starter ramps the voltage to cut that peak
  • A VFD starts the motor at close to full-load current
  • Lower inrush means less voltage dip for everything else on the supply
Illustrative chart comparing motor starting current over time: a full-voltage starter draws an inrush of around six times full-load current, a soft starter limits it to about three times, and a VFD keeps it close to full-load current while ramping up.
Protection and SCCR

Protection That Matches Every Motor

Each motor branch has short-circuit protection sized for the motor and its starter, and an overload set from the motor nameplate full-load current. We record every overload setting during testing, so maintenance has a reference when a motor is replaced.

The panel short-circuit current rating is set by the weakest part of the power circuit. When you tell us the available fault current at your site, we choose starters and protective devices that reach it and mark the rating on the nameplate.

Illustration of a motor control panel backplate: a main disconnect and control transformer at the top, a row of motor circuit protectors, a row of contactors with overload relays for each motor, and motor and control terminals at the bottom.
Schneider TeSys contactors with current transformers and neatly routed control wiring
Schneider Electric TeSys contactors with current transformers
Quoting

What to Send for a Motor Control Panel Quote

A motor list is the starting point. With these details we can choose a starting method and protection for each motor and price the panel.

  • Motor horsepower, voltage and full-load current
  • Preferred starting method, if known
  • Local, remote or PLC control
  • Available fault current at the panel
  • Installation location and enclosure type
  • Any duty or standby pump arrangement
How We Build It

From Motor List to Tested Panel

01

Review

Motor list, duty and fault current are reviewed with you.

02

Select

Starters, protection and overloads are chosen for each motor.

03

Build

The panel is built to UL 508A, wired and marked.

04

Test

Electrical checks, functional tests and recorded overload settings.

Applications

Where Our Motor Control Panels Work

Typical equipment our motor control panels run.

  • Duplex and triplex pump stations
  • Blowers and fans
  • Conveyors
  • Compressors
  • Mixers and agitators
  • Cooling towers
FAQ

Motor Control Panel Questions

What SCCR can your motor control panels reach?

It depends on the components chosen. Tell us the available fault current at the panel location and we will select starters and protection to meet it.

Do you set the overload relays?

Yes. Overloads are set from the motor nameplate full-load current you provide, and every setting is recorded during testing.

Can you build duplex pump panels with alternation?

Yes. We build multi-pump panels with lead and lag alternation and the level controls your system uses.

Do you use Schneider Electric starters?

Yes. We build with Allen-Bradley, Siemens and Schneider Electric components, matching your plant standard.

Which enclosure types do you build?

Mostly NEMA 1 for clean indoor rooms, NEMA 3R for outdoor sites, NEMA 4 for hose-down areas and NEMA 4X where corrosion is a concern. Tell us where the panel will be installed and we will recommend a rating.

Related

Related Panels & Services

UL 508A Control Panels

What the UL 508A label covers, how SCCR is set, and what we check before a panel is labeled.

Request a Quote

Need a Motor Control Panel?

Send the motor list or your drawings. We will recommend starting methods and protection, and quote the complete panel.